Allen Bradley ControlLogix 1 m RM Fiber Optic Cable 1756-RMC1

$129.00

  • In Stock!

  • Manufacturer: Allen Bradley – PLC
  • Product Type: PLC/Programmable Logic Controller
  • Part Number: 1756-RMC1
  • Series: ControlLogix
SKU: 1756-RMC1 Category:

Description

The 1756-RMC1 cable is an Allen-Bradley ControlLogix series connector cable. It is 1 meter or 3.3 feet in length. The 1756-RMC1 connector cable is made to be used with the Allen-Bradley ControlLogix 1756-RM2 and 1756-RM2K redundancy modules in redundancy systems. It is the shortest cable that is available for these modules. The 1756-RMC1 connector cable can withstand a maximum ambient operating temperature of 70 degrees Celsius or 158 degrees Fahrenheit with up to 95% non-condensing relative humidity.

  • Module Type: Fiber Optic Cable
  • Length: 3.28 feet (1 meter)
  • Wavelength: 1300 Newton Meters
  • Transmission: Less than 1000 MB-Second
  • Channels: 1
  • Operating Temperature: 32-140 Fahrenheit (0-60 Celsius)
  • Enclosure: Open
  • Wire Size: 20 AWG
  • Dimensions: 5.51 x 4.41 x 5.71 inches
  • Operating Temperature: 32-140 Fahrenheit (0-60 Celsius)
  • Enclosure: None

The Allen-Bradley 1756-RMC1 is a fiber-optic communication cable required for connecting ControlLogix redundancy modules. It has a length of one meter or 3.28 feet. It is part of the series of Bulletin 1756-RMCx Cable Series that come in a variety of lengths. These are compatible with both standard and extreme-environment modules. Building a ControlLogix Redundant Controller System requires one or two of these cables. Because redundancy modules and chassis do not ship with these connectors, order them separately before system assembly.

The 1756-RMC1 Redundancy Module Fiber-optic Cable is connected at the bottom of the module, in a downward orientation. Before connecting this, remove its protective caps. Because it contains optical fibers, do not make sharp bends in the cable. The LC connector coupler can be used to keep the cable from bending. This also allows easy connection and disconnection without needing to remove the module from the chassis.

Make sure that the location that the 1756-RMC1 Connector runs through is not prone to activities that can cause it to be run over, abraded, cut, or otherwise damaged. A redundant fiber cable system can tolerate one of multiple faults on a single channel. Network operation would become unpredictable if a fault occurred on both channels.

Additional information

Weight 0.08 kg

Reviews

There are no reviews yet.

Be the first to review “Allen Bradley ControlLogix 1 m RM Fiber Optic Cable 1756-RMC1”

Your email address will not be published. Required fields are marked *